HICLOVER incinerator exert the advantages and discard the disadvantages of the same kind of equipment at domestic and abroad. It is an unique and international advanced medical waste incineration equipment. The equipment is small size, high efficiency, reasonable process, leading technologies and a high harmless degree, ideal garbage treatment equipment for hospital, laboratory, hotel, station, etc. […]
Author Archives: hiclover
INCINERATOR DESCRIPTION The Model is for up to 300kgs capacity per batch load and will burn at around 55kgs per hour. The unit has top loading design and has a heavy duty refractory cement lining for maximum heat retention. Unit have large top lid for easy loading, and specially designed front ash door, for ash […]
Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless steel… Items/Model TS150(PLC) Principle Waste Incineration Treatment Burn Rate Average 150 kg/hour *(50/100/200kgs/hour […]
Primary combustion Diesel/LPG/LNG burning primary combustion chamber/primary combustion zone Secondary combustion Residence time in the secondary chamber not less than 2 seconds Both primary and the secondary temperatures maintained until all the waste has been completely combusted Chimney Chimney with a minimum height of 4 meters above ground level Minimum exit velocity of the emissions […]
Containerized Incinerator is one type of mobile incinerator. we build the incinerator and mounted the incinerator into shipping container(20′ container or 40′ container), with necessary Basic work, such as flooring, lighting, wiring, etc. Items/Model CA30 Picture Burn Rate Average 10 kg/hour Feed Capacity Average 30kg per feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber […]
Key Features: — Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator. — Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators. — System solutions for medical waste environmental. — […]
Incinerator Type: Containerized, diesel fueled Burning Rate:100–120kg/hour Minimum Operating Temperature:850o C(primary combustion) Maximum Operating Temperature:1450 oC(Afterburner chamber) Secondary Burning Capacity:Compulsory Density Insulation:20mm High Refractory Casting:Minimum 65mm Heavy duty refracting lining to withstand:1500 oC Average burn out time :maximum:3 hrs Fuel type:Diesel Fuel Consumption in L/hr:7.5 to 9 Residence time in secondary chamber:2sec Residue ash pot […]
Waste Incinerator Model TS150 PLC, Overview This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion chamber with 02 sets oil burner, batch load incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. […]
Gasified incineration for burning medical wastes. Fuel type: Natural Gas Burning Capability: – 30-50 kg/time – Daily 3-6 times Incinerator size: max 2000x1200x3200 mm Burning room volume: – Gasification room max 0.7 m3, – Secondary burning room max 0.5 m3, Size of the filling entrance: max 650×850 mm Air blower: max 0,5 kW Combustion-support combustion […]
Waste Incinerator Model TS150 PLC, Overview This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion chamber with 02 sets oil burner, batch load incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. […]
Load Capacity minimum: 1500 kg Burner fuel type: Diesel Burner fuel rate max.: 20-25 Liter diesel/ per hour Burners minimum: 3 Burning rate minimum: 200-300kg/per hour Furnace bar area minimum: 2 м3 Fuel tank capacity minimum: 300L Main chamber burning temperature min. 1100 0C Afterburner chamber burning temperature min. 1300 0C Power supply 220V Incinerator […]
Average 50-100 kg/hour Burn Rate Items/Model TS75(PLC) Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200-300 kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Face Oil Paint 800℃ Combustion Chamber 768 Liters (0.768M3) Internal Dimensions 1200x800x800mm Secondary Chamber 384 Liters (0.384M3) Smoke Filter Chamber Yes Feed Mode Manual Voltage 210/240V 50Hz 1P […]
Incinerator Model TS250 PLC, Overview This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 1800Liters (1.8m3, TS250 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator […]
Main unit Application For incineration, general and pathological Capacity 50 – 60 kg/h burn rate Type Two combustion chambers type; primary and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time Minimum 8 hours daily Operating temperature From 850 0C to 1200 0C, Automatic controlled Residual Ash […]
Waste Incineration Treatment Diesel Oil type Model TS150 Main Parts List as below: Primary combustion chamber Secondary combustion chamber smoke filter chamber incinerator PLC control case chimney, 10meters, stainless steel Italy Oil fule burner oil tank 300liters with full spare parts: oil burner, air blower, temperature thermocouple
50 to 60kg/hr and 100 to 120kg/hr diesel powered incinerator.1. Capability to Incinerate the Following Types of Waste: Household waste, glass, steel, aluminum cans and window extrudes, steel cans (crushed), timber, tires, white goods, plastic bottles, pressure packs, medical waste and quarantine waste. 2. Required Incinerating Capacity: Approximately 4,500 tons per year. The incinerator must […]