Author Archives: hiclover

Model TS30 oil terminated waste small incinerator 30kgs

Model TS30 oil fired waste small incinerator 30kgs/hr. Items/Model TS30( PLC) Picture Melt Rate Typical 20-30 kg/hour Feed Capability Typical 60kg per feeding Control Setting PLC( Programmable Reasoning Controller Incinerator) Burning Chamber 330L Inner Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Setting Handbook Feeding Voltage 220V Power 0.5 Kw Oil Consumption (kg/hour) […]

Containerized Mobile Incinerator Model CA50

Waste Incinerator (Containerized Mobile Burner) Capacity: Typical 50 kgs per hr Design CA50 Interior Dimensions 100 x 80 x 70 cm Main Item List Main Burning Chamber Additional Burning Chamber Smoke Filter Chamber Burner Control Situation Chimney:5.0 Meters *( upgrade to Stainless-steel, cost-free price) Italy oil/gas heater: 02 units Oil Container (if oil fuel): 200Liters […]

Medical Waste Incinerator Capacity Standard 100kgs per hour

Temperature Level Show & & PLC Control Instance Main Burning Chamber Incinerator Text Italy Oil/Gas Heater ***Primary Combustion Chamber *** Second Combustion Chamber *** Smoke Filter Chamber ***Chimney:10.0Meters *** Burner PLC Control Instance ***Italy oil/gas burner: 02 units ***Oil Tank (if oil fuel): 200Liters Items/Model TS100( PLC) Concept Waste Incineration Treatment Burn Price Standard 100 kg/hour […]

Dual heat burners as well as double chamber burner Burning ability up to 30 Kg per hour with wet scrubber

Dual heat burners and dual chamber incinerator Burning capacity up to 30 Kg per hour Main Product List Primary Combustion Chamber(Main body stainless steel) Secondary Combustion Chamber(Main body stainless steel) Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Main body stainless steel) Incinerator Control Case Chimney:5.0Meters  Stainless Steel Italy gas burner: 02 sets Oil Tank (if oil fuel): […]

hiclover waste burner extra parts

We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products […]

Containerized Mobile Burner Pre-assembled, containerized type

Version CA100 Photo Waste Therapy Medical Waste Incineration Therapy Feed Ability Ordinary 100-200 kgs per feed Burning Rate Typical 100-120 kgs per hr Burning Time per Feed Standard 1-2 hr Control Setting PLC( Programmable Logic Controller Incinerator) Voltage 220V Power 1.0 Kw Fuel Diesel oil Burner Italy Heater Feed Mode Handbook Temperature Monitor Digital Display […]

Pyrolytic Dual Chamber Incinerator Small Size : Burning Price : 30-45 kg/hr ; Optimum Load Capability : 400 kg

Items/Model TS50( PLC) Picture Principle Strong Waste Incineration Burn Price 30-45 kg/hour Control Mode PLC( Programmable Reasoning Controller Burner) Burning Chamber 560L Inner Measurements 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Setting Manual Voltage 220V Oil Intake (kg/hour) Typical 13.3 Gas Consumption (m3/hour) *** Temperature Display Digital Show Temperature Level Defense Yes Oil […]

Tool Dimension : Burning Rate : 60-80 kg/hr Pyrolytic Double Chamber Incinerator

Items/Model TS100( PLC) Photo Concept Waste Incineration Treatment Burn Price 60-80 kg/hour Control Mode PLC( Programmable Reasoning Controller Incinerator) Combustion Chamber 1200L Interior Measurements 120x100x100cm Second Chamber 600L Smoke Filter Chamber Yes( Dry Scrubber) Feed Setting Manual Voltage 220V Oil Consumption (kg/hour) Typical 20.4 Gas Intake (m3/hour) *** Temperature Monitor Digital Present Temperature Level Defense […]

Plus Size Burning Price : 150-200 kg/hr Solid Waste Devices Primary and Second Combustion Chamber Burner

Items/Model TS500( PLC) Picture Concept Waste Incineration Treatment Burn Price 150-200 kg/hour Control Setting PLC( Programmable Logic Controller Burner) Combustion Chamber 2700L Interior Dimensions 190x120x120cm Second Chamber 1300L Smoke Filter Chamber Yes Feed Mode Handbook Voltage 220V Oil Intake (kg/hour) Ordinary 28 Gas Usage (m3/hour) *** Temperature Display Digital Display Temperature Security Yes Oil Tank […]

Mobile Cremation Devices

Design CA-200 Image Burning Rate Ordinary 100 kgs/hour Key Burning Chamber 2000 Liters Additional Burning Smokeshaft Yes Feed Mode Guidebook Voltage 220V Power 3.0 Kw Fuel Kind Diesel Oil Burner Italy Original Oil Usage (Diesel Oil) Typical 53 kg/hour Interior Dimensions 230 x 100 x 90cm (primary chamber) External Measurements 290 x 200 x 170cm […]

Medical Facility Waste Monitoring

Hospital Waste Management as well as Competitive prices as Pakistan is a competitive market. We have a complete setup with Office, Customer Relations, Import / Export, Biomedical Department, Application Support Department & Project Designing Department.Description        Minimum Requirements Design standard    Multiple chamber incinerator to the design of EPA  standards, Air pollution control Description of the […]

dispose Medical waste IV

the incinerator can be made use of to get rid of Medical waste IV, used needles, made use of syringes, scalpels, used dressing material, individual safety devices like gown, gloves and so on truncated body parts, excreta from clients and also various other research laboratory waste.incineration devices that can handle a mix of clinical as […]

CONTAINERIZED BURNER FOR INCINERATING HAZARDOUS AND ALSO NON HAZARDOUS WASTES

CONTAINERIZED BURNER FOR INCINERATING HAZARDOUS AND NON HAZARDOUS WASTES (BOTH DOMESTIC As Well As INDUSTRIAL) AT A MINIMUM PRICE OF 300KG/HR WITH THE COMPLYING WITH REQUIREMENTS: Ø PRIMARY CHAMBER VOLUME 7.2 M ³ Ø BURNING CAPACITY 300Kgs/hr. Ø PRIMARY CHAMBER TEMPERATURE 850 ⁰ C AND SECONDARY CHAMBER TEMPERATURE LEVEL 1100 ⁰ C Ø REFRACTORY DENSITY […]

STRONG WASTE INCINERATOR

Primary chamber – Consists of a monolithic high grade refractory concrete with high grade insulation backing, . Utilising a refractory hearth or equivalent for continuous ash removal. Secondary Chamber – Consists of high density, low thermal mass refractory ceramic fibre with an innovative low emissivity protective coating. bio medical waste treatment plant ( Incineration )with […]