Capacity: 20KG/Hr, Temp Range: 600 Deg. C – 1100 Deg. C Fuel Supply: Natural Gas/Diesel Dual Combustion Chamber Complete Scrubbing System (Dual Resultant Gas Washer), Dual Blower, Chimney Height: 8m Electric Supply: 220/240Volt, Single Phase 1. Type of waste: Trash 2. Any other type: 3. Quantity of waste generated per day in kg: (50 Ton […]
Author Archives: hiclover
Major components are – Ethanol, Paraffin, Silicon, Aluminium chloro hydrate, Bentone ,LPG quote for incinerators for industrial chemical wastes treatment, 1 burning rate must be Average 30kgs/h 2 inside of chamber material must be refractory concrete cement 3 it works in three system diesel oil/ Natural gas or LPG 4 voltage must be 220V 5 […]
Stack: Type: Wire Supported MOC: Mild Steel of ISstd Height :3 Meters or more • PROCESS AT LEAST 1 METRIC TON OF WASTE PER DAY • OPERABLE BY 1 PERSON, WITH NO TRAINING REQUIRED • REGULAR MAINTENANCE CAN BE COMPLETED BY 1 PERSON WITH LIMITED TRAINING • REGULAR MAINTENANCE SHOULD NOT EXCEED 1-HOUR PER DAY […]
Primary Combustion Chamber Waste Charging Door: Provided with refractory lining with sealing gaskets Ash Removed Door: Provided with refractory lining with sealing gaskets Outer Body MOC: Mild Steel, 5mm Primary Chamber: Stainless Steel Operating Temperature :800. ± 50◦C Insulation: Insulation Brick Heating Elements Type: Kanthal Al Grade Power Consumption: 75 KW ( Initial Load ) […]
1. Is the residence time more than 2 seconds? 2. Is the primary and secondary air preheated? 3. Could it be provided as a continuous system? 4. Is there a monitoring system for operational parameter? (temperature) 5. Is there a data logging system? 6. Does it provide for control interventions to adjust waste feed, grate […]
Burning rate: 250 Kg/hr. It should be able to Operate not Less than 10 hours/day This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… Design Specification: Types A, B, C, D, and E of medical waste “PYROLYTIC” combustion, by controlling the gasification of waste. The incinerator […]
GOODS: ONE INCINERATORS IN ACCORDANCE WITH THE SUPPLIER’ REQUIREMENT S OWN PROPOSED SPECIFICA TION/ CONFIRM ATION […]
GOODS: ONE INCINERATORS IN ACCORDANCE WITH THE SUPPLIER’ REQUIREMENT S OWN PROPOSED SPECIFICA TION/ CONFIRM […]
TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals INTRODUCTION All the incinerators to be supplied and installed must meet the Government of Kenya waste Management Regulation 2006 in particular 3rdschedule regulation (26, 47) pertaining classification, standards, criteria, and procedure for installing/operating incinerators as authored by the National Environmental Management and Coordination (waste management) regulation 2006, legal […]
1) Policy – Waste disposal management shall be taken special note to prevent hospital infection. – Infections wastes shall be managed, stored strictly and burned by a incinerator located at hospital site. 2) Waste Disposal Plan a)Classification – Medical wastes in hospital are classified as follows; Infections Waste Specially-controlled waste Organ, needle, etc. Industrial waste […]
“PYROLYTIC” combustion, by controlling the gasification of waste The incinerator manufacturer must avoid the release of black smoke and fine dust, during the loadings. It shall be able to reduce the volume of wastes by 98%. It shall be able to hold emission in the second burn with gas residence of not less than 2 […]
The incinerator plant shall incorporate a control panel for its operation. On the control panel we shall have a visual display of the chamber temperatures. This visual display must control and monitor the incinerator and his performance. Capacity of destruction in weight shall be 60 Kg/h. It should be able to operate not less than […]
Petrol: diesel Consumption: 8-10liter/hour Capacity: to cremate (carrion and spoils) 350-400kg/hour Temperature: 900-1350?C Operation temperature: -30~40?C Incinerator weight: 1800-2000 kg Volume: 0.70-0.80m/cube Exterior dimension: 1.4-1.6*1.0-1.15m (L*W) An incinerator represents a complete solution to the problem of disposal of all hospital waste types. The liquid fuel is diesel. The […]
Complete combustion converts waste into inert bottom ash with minimal creation of smoke, fly ash and hazardous gases. Several factors influence this process including the heating value, wetness and chemical composition of the waste itself, operating conditions in the burn chamber (i.e. temperature, holding time and turbulence) and operator skill. The method used is important […]
* Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. * A secondary injection of air to ensure perfect oxygen content. 19. A control box ensuring the complete cycle of combustion. 20. Fan: * Electro-ventilator distributing the secondary […]
* medical incinerators, The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on the outside sheet metal. * Composition of the refractory; ? Refractory concrete : ? . Thickness : ≥100 mm ? . Nature: 42% […]