Version YD-30 Mobile Kind Picture Burning Price Ordinary 30 kgs/hour Feed Capacity Common 60 kgs/feeding Chamber Text Stainless-steel Mobile Attribute With Wheel and likewise Brake Main Burning Chamber 280 Liters Second Combustion Chamber 150 Litres Mix Burning Chamber Yes Feed Setting Handbook Voltage 220V Power 1.5 Kw Gas Kind Diesel Oil Burner Italy Original Oil […]
1.The double chamber incinerator shall preferably be designed. Air supply in the primary and secondary chamber shall be regulated between 30%-80% and 170%-120% of stoichiometric amount respectively. Flow meter/suitable flow measurement device shall be provided on the primary and secondary air ducting. The combustion air shall be supplied through a separate forced draft fan accounting […]
BURNING RATE: -100 -150 kgs per hr MINIMUM OPERATING TEMPERATURE: 800-1000 oC (PRIMARY BURNING) MAX OPERATING TEMPERATURE LEVEL LEVEL: 1000-1200 oC (AFTER HEATING UNIT BURNING) SECONDARY MELTING ABILITY: COMPULSORY THICKNESS INSULATION: 50 mm high Refractory ability: mins 114mm STURDY REFRACTING LINING TO WITHSATND 17500C AVEARGE WEAR OUT TIME: MAXIMUM 3HRS GAS KIND: GAS OIL (DIESEL) […]
Mobile Containerized Waste Incinerators pets or human cremation emergency use Layout CA-200 Photo Burning Rate Common 100 kgs/hour Key Burning Chamber 2000 Liters Secondly Burning Smokeshaft Yes Feed Establishing Hand-operated Voltage 220V Power 3.0 Kw Gas Kind Diesel Oil Heater Italy Original Oil Usage (Diesel Oil) Typical 53 kg/hour Interior Measurements 200 x 100 x 100cm […]
Medical waste is currently managed via an old medical waste incinerator; which also manages the associated medical waste delivery and ash removal arrangements.Pathological waste: organs, tissues, surgical specimens, bodily fluids removed during surgery or autopsy. Mix and moisture content not known.Allow for weekly deliveries @ 8 hour per day operation = 11 kg per hour […]
Items/Model TS250( PLC) Photo Idea Waste Incineration Treatment Burn Price Average 250 kg/hour Feed Ability Criterion 400kg/feeding Control Establishing PLC( Programmable Reasoning Controller Burner) Combustion Chamber 2000L Inner Measurements 210x88x110cm Second Chamber 1000L Smoke Filter Chamber Yes Feed Setting Guidebook Voltage 220V Power 2.0 Kw Oil Consumption (kg/hour) Regular 24.2( DO) Gas Consumption (m3/hour) *** […]
General specifications of a 100 kg/hr incinerator No. Description Parameter value model HICLOVER YD100 1 Machine working mode Oil + Power Oil + Power 2 Voltage 220V C 3 phase or 1 phase 220V 1P 3 Oil consumption (lit/hr) Average 25-32 lit/hr/chamber Average 33Liters/hour/total incinerator 3 burners 6 Incineration rate 100 kg/hr […]
the entire carcass of animals ( cattle , horses , Sheep, pigs , etc.) , as well as biologically hazardous waste Products in the fuel stove . ? Opening Doors – the closure and fixation automated system , Which are managed remotely by the operator . ? designed to work in long mode and fast […]
Incinerator Parts Mineral Insulated Thermo couple sensor K-Type 300SS K type 300SS: M27*2, 300mm Ins,2520 S.S, 2.5mm core HICLOVER – Medical Environmental WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: [email protected]Email: [email protected] Nanjing Clover Medical Technology Co.,Ltd. 2020-06-27 smart
● Able to burn 25-30kg per hour ● Consist of two chambers to ensure significant reduction in emission ● Be capable of temperature in range of 800c to 1000c ● Low maintenance design ● Must be Diesel fuelled ● Need more than 15amp 220- 250V power ● kW Consumption power consumption to be stated ● […]
Items/Model TS50M Picture Melt Rate Typical 50 kg/hour Feed Capacity Average 50-150 per feeding Control Setting PLC( Programmable Thinking Controller Incinerator) Combustion Chamber 450L Internal Measurements 75x75x80cm Extra Chamber 225L Smoke Filter Chamber Yes Feed Setting Manual Feeding Voltage 220V Power 0.5 Kw Oil Use (kg/hour) Average 13.3 Gas Use (N.G, m3n/Hour) Ordinary 16 Gas […]
Style for Pets Cremation Service Movable system & & & & Vehicle. Door Independent Placement for Small Pet Incinerator with Movable platform & Auto. Door and Design for Pets Human Cremation Business Design A1500 Image Burning Rate Typical 150 kgs/hour Feed Capacity Standard 350 kgs/feeding Main Burning Chamber 1500 Liters Second Burning Chamber 500 Litres Mix […]
Standard 30kgs per hr *** Secret chamber( 200Liters) *** 2nd chamber *** Mix burning chamber *** Stainless-steel smokeshaft( 1meter) *** Italy made oil heater( 2sets) *** Dry Scrubber *** Weight 1.7 T( can decrease to 1.0 Lot) Trick Spare Components( Standard for incinerator, and also price contain presently): *** 2 collections Italy Oil Heating system […]
Medical Waste Incinerators in Stock. Twitter: https://twitter.com/hiclovercom Phone/WhatsApp/Wechat: +8613813931455, Web: www.hiclover.com Web: www.clover-incinerator.com Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless […]
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L 600L […]
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production Shipping Volume Shipping Weight Delivery Location TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set […]