Oil tank with 2000Liters capacity Items/Model TS150( PLC) Image Principle Waste Incineration Therapy Burn Rate Requirement 100-150 kg/hour Feed Ability Standard 750kg/feeding Control Setting PLC( Programmable Thinking Controller Burner) Text Steel 8mm thickness Chamber Product High Alumina Fire Brick Wall Surface, 1750 ℃ Rate Paint for outside face 800 ° C Rate Combustion Chamber 1570L […]
The incinerator plant shall incorporate a control panel for its operation. On the control panel we shall have a visual display of the chamber temperatures. This visual display must control and monitor the incinerator and his performance. Capacity of destruction in weight shall be 60 Kg/h. It should be able to operate not less than […]
Incinerator Variation CA100, Summary 100Kg/Hour Burning price with Secondary burning Capability This design is tiny medical waste incineration gadgets. Building and building is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Animal feed chamber is 560Liters (Model CA100). Primary & Secondary combustion chambers and smoke filter chamber with firebrick and refractory […]
Waste Incineration Treatment Burn rate (rate of waste incineration) -at least 50 kg per hour Oil tank smoke filter chamber Items/Model TS100( PLC) Image Principle Waste Incineration Therapy Burn Price Average 50-100 kg/hour Feed Capability Average 200kg/feeding Control Establishing PLC( Programmable Thinking Controller Incinerator) Burning Chamber 1000L Internal Measurements 120x100x90cm 2nd Chamber 540L Smoke Filter Chamber […]
All particles of the waste should achieve a high level of sterilization and not just “disinfection” due to the continuous agitations Description of the Treatment Cycle of the processor i) Loading * The waste has to be loaded by dropping bagged and or boxed waste into the open loading door on the vessel. * The […]
HICLOVER incinerator exert the advantages and discard the disadvantages of the same kind of equipment at domestic and abroad. It is an unique and international advanced medical waste incineration equipment. The equipment is small size, high efficiency, reasonable process, leading technologies and a high harmless degree, ideal garbage treatment equipment for hospital, laboratory, hotel, station, etc. […]
Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless steel… Items/Model TS150( PLC) Principle Waste Incineration Treatment Shed Rate Average 150 kg/hour […]
Containerized Incinerator is one type of mobile incinerator. we build the incinerator and mounted the incinerator into shipping container(20′ container or 40′ container), with necessary Basic work, such as flooring, lighting, wiring, etc. Items/Model CA30 Image Shed Rate Common 10 kg/hour Feed Capability Average 30kg per feeding Control Establishing PLC( Programmable Reasoning Controller Burner) Combustion […]
Medical Waste Shredder Capacity: Should be 150 liters. Should be capable to shred up to 100 liters of the treated waste. 7 The technology should be capable to treat hospital waste including sharps like needles, lancets, scalpels and soft materials like bandages. Must render the waste to be unrecognizable. Following […]
Petrol: diesel Consumption: 8-10liter/hour Capacity: to cremate (carrion and spoils) 350-400kg/hour Temperature: 900-1350?C Operation temperature: -30~40?C Incinerator weight: 1800-2000 kg Volume: 0.70-0.80m/cube Exterior dimension: 1.4-1.6*1.0-1.15m (L*W) An incinerator represents a complete solution to the problem of disposal of all hospital waste types. The liquid fuel is diesel. The […]
The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by basic designation only. A1) Technical Specification: Incinerators All types of diesel fired incinerators suitable for HCW may be offered as long as they can safely treat medical waste. The equipment should be compliant […]
Piping and stack connection locations and sizes. Technical data including temperature rating and arrangement of refractory and insulation. Weights of unit and loading diagram of foundation. Evidence that contractor has coordinated support requirements with foundation design. Recommended anchorage to foundation. Seismic requirements apply. Submit calculations by professional engineer. Predicted external surface […]
* Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. * A secondary injection of air to ensure perfect oxygen content. 19. A control box ensuring the complete cycle of combustion. 20. Fan: * Electro-ventilator distributing the secondary […]
Key Features: — Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator. — Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators. — System solutions for medical waste environmental. — […]
Waste Heater Design TS150 PLC, Review This design is small-scale waste incineration tools for tiny waste end result. Construction is dual/double combustion chamber with 02 sets oil burner, batch load incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of […]
Waste Incinerator Design TS150 PLC, Testimonial Construction is dual/double combustion chamber with 02 sets oil burner, batch load incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. Primary Combustion Chamber: […]