The incinerator shall be equipped with a Diesel oil tank that will be supplied with DO from our DO tank located in the power station. The tank shall be equipped with level switches and appropriate solenoid valves for automatic filling of the tank. The tank shall also be equipped with a magnetic level indicator, level […]
Average 50-100 kg/hour Burn Rate Items/Model TS75( PLC) Principle Waste Incineration Therapy Burn Cost Average 50-100 kg/hour Feed Ability Ordinary 200-300 kg/feeding Control Mode PLC( Programmable Reasoning Controller Burner) Face Oil Paint 800 ℃ Combustion Chamber 768 Liters (0.768 M3) Inner Measurements 1200x800x800mm Added Chamber 384 Liters (0.384 M3) Smoke Filter Chamber Yes Feed Setting […]
Burner Design TS250 PLC, Review This design is small waste incineration tools for little waste result. Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 1800Liters (1.8m3, TS250 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator […]
Waste is thermally rotted in the main chamber at temperature degrees of 800 ° C +. The resulting aeriform products are entirely oxidized in the second chamber at higher temperature levels with ample resident time. Various other specs are as adheres to. A burning chamber of waste: * Flawlessly limited door for the hands-on loading […]
Spare part list –After burners Item description No of required Motor 2 Control box 2 Pump couplings 4 Photo cells 2 Sets ht. leads 2 Sets electrodes 4 Oil valve 1 Nozzle 2 Spare part list –Ram loader Item description No of required Reed switch 4 Seal kit 1 Medical waste incinerator […]
Medium Unit – to handle an average waste production of 500 kg/day.Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg.Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day). Items/Model TS50( PLC) Image Idea Waste Incineration Therapy Melt Price Criterion 50-100 kg/hour Feed Capability Average 200-300 kg/feeding Control Mode PLC( Programmable Reasoning Controller Burner) Optional Upgrade Containerized Mobile Kind Burner ISO 20′ ′ ′ ′ Complete Container Burning Chamber 560L Interior Measurements 1000x800x700mm 2nd Chamber 280L Smoke Filter Chamber Yes Feed Setting Manual […]
* medical incinerators, The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on the outside sheet metal. * Composition of the refractory; ? Refractory concrete : ? . Thickness : ≥100 mm ? . Nature: 42% […]
We supply Double Chamber Incinerator with primary chamber size average 1570Liters and burnning rate 50kgs per hour,100kgs per hour,150kgs per hour,200kgs per hour. the incinerators are now ready for shipping. Contact with us for quick respond: +86-13813931455 Secret Product Listing per 01 collection Trick Burning Chamber Secondly Burning Chamber Smoke Filter Chamber Incinerator PLC Control Situation Smokeshaft:10.0 Meters […]
The heater with dual/double combustion chamber as well as completely dry filter chamber, two gas burner from Italy created, hot sale version for little range waste result, the ability is 30kgs per hr as well as likewise 50kgs per human resources. Heater is not a cost-effective gadgets, generally the tiny range version’s cost around $5,000 […]
HICLOVER now supplies additional components including: — — — — Burners (diesel oil, LPG or gas) — — — — Facet for heaters — — — — Fire ropes — — Incinerator chamber maintenance items — — — — Air Follower smart
The switchboard shall operate in a room with the following prevailing conditions: – Maximum ambient temperature of 40 0C – Maximum relative humidity of 95% – Saline atmosphere – Altitude: at sea level – Climate type: Wet and humid coastal conditions with cyclone associated to a small tropical island in the Indian Ocean MAIN […]
1. Capacity of destruction in weight: 60 Kg/h. 2. It should be able to operate not less than 10 hours/day 3. This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… 4. Design Specification : Types A, B, C, D, and E of medical waste 5. “PYROLYTIC” […]
The panel and parts hereof shall have the following characteristics: Finish All metal parts shall receive a treatment taking the prevailing environment conditions into account. The top paint colour shall be the Manufacturer’s standard. Auxiliary Wiring All […]
All numbering will be carried out in compliance with the corresponding circuit diagrams and wiring list. Component Marking All components inside the switchboard shall be marked for identification. The marking shall be effected by material resistant to the prevailing environment conditions. All […]
We seek a lasting growth consequently we are adopting an enduring medical waste monitoring system, that includes constructing a modern long lasting incinerator that will certainly not just provide for our center yet also for the numerous other centers in the larger place of the location. Waste kind: health care danger waste and standard waste […]
Waste kind: health care waste Waste density: 125 to 350Kg/M3 Waste calorific well worth: 4000KCAL/kg Dampness web content: 10– – 25%. Approximated ash deposit: 5– – 10%. Nominal ability: 50kg/hr set lots. 2nd chamber: 2 [e-mail protected] C. Environmental: NEMA ACT (EMCA) 1999, Waste Keeping track of plans, 2006. Trick Burning chamber:. The […]